Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication

Product Details
Customization: Available
Task: Adjust
Structure: Combination
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
to see all verified strength labels (26)
  • Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
  • Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
  • Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
  • Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
  • Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
  • Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Overall dimension
  • Company Profile
Overview

Basic Info.

Model NO.
DRG-2200-A
Certification
RoHS, CCC, ISO: 9001, CE
Condition
New
Customized
Non-Customized
Number of Channels
1input/1output
Input Signal
RS485 Digital Signal (Half Duplex)
Output Signal
RS485 Digital Signal (Half Duplex)
Power Supply Mode
20~35V DC
Installation
35mm DIN Rail
Transport Package
Box
Specification
PC+ABSflame retardant
Trademark
PARAGON
Origin
China

Product Description


 
 
Product Description
Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
Detailed Photos
Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
Product Parameters
General
Number of channels 1input/1output
Insulation strength 1500VAC/min between intrinsically safe/non intrinsically safe terminals, 1000VAC/min between non intrinsically safe terminals
Output accuracy 0.1% F.S.
Transmission delay ≤10uS
Signal transmission rate <56Kbps
Temperature drift 0.01%F.S/C
Transmission control mode Half-duplex
Power distribution for on-site instruments 24V/50mA
Distribution voltage error ±10%
Insulation resistance Non intrinsic safety end - intrinsic safety end≥100MΩ, power supply - non intrinsic safety end≥100MΩ
Electromagnetic compatibility Compliant with IEC 61326-1 (GB/T 18268), IEC 61326-3-1
EX marking [Ex ia Ga]IIC
Weight About 150g
Connected field equipment Installed in a safe location and capable of communicating with Zone 0 frequency equipment with IIA, IIB, and IIC hazardous gases
Applicable locations Zone 0, Zone 1, Zone 2, IIA, IIB, IIC hazardous areas
Input data
Input signal range RS485 digital signal (half duplex)
Output data
Output signal range RS485 digital signal (half duplex)
Power supply
Supply voltage(Ue) 20~35V DC
Power protection Reverse protection of power supply
Power consumption About 2W (24V power supply, 5V, 100mA)
Power supply mode Independent power supply
Power connecting mode Terminal power supply;Base power supply
Overall dimension
Centralized power supply
Depth 120.8mm
Height 113mm
Width 18.3mm
Independent power supply
Depth 110mm
Height 108mm
Width 18.3mm
Housing
Material PC+ABSflame retardant
Degree of protection IP20
Flammability rating UL94/V0
Colour White+Grey
EMC data
Electrical fast transient/burst immunity Compliant with:IEC 61326-1;A-leve
Surge immunity Compliant with:IEC 61326-1;B-leve
Radiated,radio-frequency,electromagnetic field immunity Compliant with:IEC 61326-1;conform to basic requirements
Electrostatic discharge immunity Compliant with:IEC 61326-1;A-leve
Immunity to conducted disturbances, induced by radio-frequency fields Compliant with:IEC 61326-1;conform to basic requirements
Low frequency common mode conduction Compliant with:IEC 61326-1;conform to basic requirements
Operating conditions
Continuous operating temperature -20ºC~+60ºC
Storage temperature -40ºC~+80ºC
Relative humidity 10%~90%
Environmental requirements There should be no strong vibrations, impacts, high currents, sparks or other electromagnetic induction effects in the surrounding environment. The air should not contain media that corrode chromium, nickel, and silver coatings, and should not contain flammable or explosive substances
Connection data
Conductor cross section solid range 0.5~2.5mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M3
Stripping length 8mm
Connection method Screw connection
Tightening torque min. 0.5 Nm
Tightening torque max. 0.6 Nm
Installation
Installation method DIN35mm
Overall dimension

1. Base centralized power supply typeAdvanced RS485 Isolated Safety Barrier for Half-Duplex Communication2. Terminal powered type

Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication

Company Profile

 


Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
 
Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
Advanced RS485 Isolated Safety Barrier for Half-Duplex Communication
Advanced RS485 Isolated Safety Barrier for Half-Duplex CommunicationAdvanced RS485 Isolated Safety Barrier for Half-Duplex Communication

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier