Customization: | Available |
---|---|
Certification: | RoHS, CCC, ISO: 9001, CE |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
General | |
Number of channels | Dual channel input |
Switch capacity | |
Three normally open contacts | AC15:5A/250VAC |
DC13:6A/DC24V | |
Rated heating current Ith | 5A |
Insurance level | 6A fast or 4A slow |
Usage category | AC-15,DC-13 |
Time | |
Dual channel input time | Unlimited |
Safe output time under rated voltage | Manual start for 35ms |
Safe disconnection time under rated voltage | 10ms |
Contact material and structure | AgSnO+0.2um Au, forced open contact |
Contact resistance | ≤100mΩ |
Mechanical life | 10 million times |
Operation frequency | 6 times/minute |
Status display | Three green LEDs |
Start button monitoring | Manual start/automatic start |
Rated insulation voltage | 300V (pollution level 2 according to IEC60947-5-1) |
Rated impulse withstand voltage | 2500V (Class 2 overvoltage according to IEC60947-5-1) |
Applicable | Two handed start |
Input data | |
Input channel | Dual channel input |
Input current | ≤10mA |
Wire resistance | ≤15Ω |
Output data | |
Output signal | Semiconductor output |
Output channel | 3 normally open outputs (13-14,23-24,33-34) |
One normally closed output (41-42) | |
Power supply | |
Supply voltage | 24VDC |
Voltage range | 85%~110% |
Module power consumption | ≤3W(24VDC) |
Overall dimension | |
Height | 114.5mm |
Width | 99mm |
Thickness | 22.5mm |
Housing | |
Material | ABSflame retardant |
Degree of protection | IP20 |
Flammability rating | UL94/V0 |
Colour | Grey+Yellow |
EMC data | |
Electrical fast transient/burst immunity | Compliant with:IEC 61326-1;A-leve |
Surge immunity | Compliant with:IEC 61326-1;B-leve |
Radiated,radio-frequency,electromagnetic field immunity | Compliant with:IEC 61326-1;conform to basic requirements |
Electrostatic discharge immunity | Compliant with:IEC 61326-1;A-leve |
Immunity to conducted disturbances, induced by radio-frequency fields | Compliant with:IEC 61326-1;conform to basic requirements |
Low frequency common mode conduction | Compliant with:IEC 61326-1;conform to basic requirements |
Compliant with standards | BS EN 62061:2015,ISO 13849-1:2015,ISO 13849-2:2012, IEC EN 60204-1, ISO 13849-1 |
Safety Integrity Level (SIL) | EN954-1, maximum safety control level 4 |
Performance level (PL) | ISO 13849-1:2015,PLe |
Operating conditions | |
Continuous operating temperature | -20ºC~+60ºC |
Storage temperature | -40ºC~+85ºC |
Relative humidity | <90% RH (no condensate) |
Environmental requirements | There should be no strong vibrations, impacts, high currents, sparks or other electromagnetic induction effects in the surrounding environment. The air should not contain media that corrode chromium, nickel, and silver coatings, and should not contain flammable or explosive substances |
Connection data | |
Conductor cross section solid range | 0.5~2.5mm² |
Conductor cross section AWG min. | 12 |
Conductor cross section AWG max. | 24 |
Stripping length | 8mm |
Screw thread | M3 |
Connection method | Screw connection |
Tightening torque min. | 0.5 Nm |
Tightening torque max. | 0.6 Nm |
Installation | |
Installation method | DIN35mm |