Premium Signal Isolation Splitter for PLC Control Cabinets

Product Details
Customization: Available
Task: Adjust
Structure: Combination
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
to see all verified strength labels (26)
  • Premium Signal Isolation Splitter for PLC Control Cabinets
  • Premium Signal Isolation Splitter for PLC Control Cabinets
  • Premium Signal Isolation Splitter for PLC Control Cabinets
  • Premium Signal Isolation Splitter for PLC Control Cabinets
  • Premium Signal Isolation Splitter for PLC Control Cabinets
  • Premium Signal Isolation Splitter for PLC Control Cabinets
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Overall dimension
  • Company Profile
Overview

Basic Info.

Model NO.
DR-112
Certification
RoHS, CCC, ISO: 9001, CE
Condition
New
Customized
Non-Customized
Input Signal
0-75mv;0-250V;0-20mA;
Number of Channels
1input/2outputs
Output Signal
-10V~+10V;4~20mA
Power Supply Mode
24VDC±10%
Accuracy
0.1%Fs
Installation
35mm DIN Rail
Transport Package
Box
Specification
PC+ABSflame retardant
Trademark
PARAGON
Origin
China

Product Description

Product Description
Premium Signal Isolation Splitter for PLC Control Cabinets
Detailed Photos
Premium Signal Isolation Splitter for PLC Control Cabinets
Product Parameters
General
Number of channels 1input/1output
Output accuracy(20°C) 0.2%F.S.
Temperature drift 50ppm/K
Response time <0.05s (0~90%) (TYP)
Dielectric strength 1500VAC/1min,2mA
Insulation resistance ≥100MΩ;500VDC
Electromagnetic compatibility compliant with GB/T18268 (IEC61326-1)
Weight About 70g
Field apparatus Current source
Input data
Input signal 0~75mV;0~250mA;4~20mA
Input impedance current≤100Ω;voltage≥100KΩ
Output data
Output signal Two wire system output 4-20mA
Output impedance ≤ 500 Ω (when the internal power supply of the port is 24V)
Overall dimension
Base power supply
height 121mm
width 113mm
Thickness 13.3mm
Terminal power supply
height 110mm
width 108mm
Thickness 13.3mm
Housing
Material PC+ABSflame retardant
Degree of protection IP20
Flammability rating UL94/V0
Colour white+grey
EMC data
Electrical fast transient/burst immunity compliant with:IEC 61326-1;A-leve
Surge immunity compliant with:IEC 61326-1;B-leve
Radiated,radio-frequency,electromagnetic field immunity compliant with:IEC 61326-1
Electrostatic discharge immunity compliant with:IEC 61326-1;A-leve
mmunity to conducted disturbances, induced by radio-frequency fields compliant with:IEC 61326-1
Immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz compliant with:IEC 61326-1
Operating conditions
Ambient temperature -20ºC~+60ºC
Storage temperature -40ºC~+80ºC
Relative humidity <90% RH (no condensate)
Environmental requirements The air should not contain any medium corrupting the coat of chrome,nickel and silver.Moreover,violent quiver and impact or any cause of electromagnetic induction (such as big current or spark,etc.)must be avoided when using
Connection data
Conductor cross section solid range 0.5~2.5mm²
Conductor cross section AWG min 12
Conductor cross section AWG max 24
Stripping length 8mm
Screw thread M3
Connection method Screw connection
Tightening torque min 0.5 Nm
Tightening torque max 0.6 Nm
Installation
Installation method DIN35mm
Overall dimension

Premium Signal Isolation Splitter for PLC Control Cabinets

Company Profile

Premium Signal Isolation Splitter for PLC Control Cabinets

Premium Signal Isolation Splitter for PLC Control Cabinets
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier