Customization: | Available |
---|---|
Certification: | RoHS, CCC, ISO: 9001, CE |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
General | |
Number of channels | 1input/2outputs |
Output accuracy (20 ° C) | 0.2% F.S. |
Temperature drift | 50ppm/K |
Response time | <0.5s (0~90%) (TYP) |
Insulation strength | 1500V AC/1min,2mA |
Insulation resistance | Above 100M Ω at 500VDC |
Long term compensation | 200Ω(line resistance) |
Electromagnetic compatibility | Compliant with GB/T18268 (IEC61326-1) |
Weight | About 120g |
Connected field equipment | Two wire heating resistor; Three wire heating resistor |
Input data | |
Input signal | PT100;PT100;CU50 |
Excitation voltage | 2.5V |
Input wire break alarm current | IL≤2mA or IH≤22mA |
Output data | |
Output signal | 0~10V;0~20mA |
Output impedance | Current type ≤500Ω; Voltage type ≥10KΩ |
Power supply | |
Supply voltage(Ue) | 24VDC±25% |
Power protection | Reverse protection of power supply |
Power consumption | <2W |
Power supply mode | Independent power supply |
Power connecting mode | Terminal power supply |
Overall dimension | |
Depth | 110mm |
Height | 108mm |
Width | 13.3mm |
Housing | |
Material | PC+ABSflame retardant |
Degree of protection | IP20 |
Flammability rating | UL94/V0 |
Colour | Grey |
EMC data | |
Electrical fast transient/burst immunity | Compliant with:IEC 61326-1;A-leve |
Surge immunity | Compliant with:IEC 61326-1;B-leve |
Radiated,radio-frequency,electromagnetic field immunity | Compliant with:IEC 61326-1;conform to basic requirements |
Electrostatic discharge immunity | Compliant with:IEC 61326-1;A-leve |
Immunity to conducted disturbances, induced by radio-frequency fields | Compliant with:IEC 61326-1;conform to basic requirements |
Low frequency common mode conduction | Compliant with:IEC 61326-1;conform to basic requirements |
Operating conditions | |
Continuous operating temperature | -20ºC~+60ºC |
Storage temperature | -40ºC~+80ºC |
Relative humidity | < 90% RH(no condensate) |
Environmental requirements | There should be no strong vibrations, impacts, high currents, sparks or other electromagnetic induction effects in the surrounding environment. The air should not contain media that corrode chromium, nickel, and silver coatings, and should not contain flammable or explosive substances |
Connection data | |
Conductor cross section solid range | 0.5~2.5mm² |
Conductor cross section AWG min. | 12 |
Conductor cross section AWG max. | 24 |
Stripping length | 8mm |
Screw thread | M3 |
Connection method | Screw connection |
Tightening torque min. | 0.5 Nm |
Tightening torque max. | 0.6 Nm |
Installation | |
Installation method | DIN35mm |