PLC Control Cabinet with Emergency Stop Button Safety Relay

Product Details
Customization: Available
Task: Adjust
Structure: Combination
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
to see all verified strength labels (26)
  • PLC Control Cabinet with Emergency Stop Button Safety Relay
  • PLC Control Cabinet with Emergency Stop Button Safety Relay
  • PLC Control Cabinet with Emergency Stop Button Safety Relay
  • PLC Control Cabinet with Emergency Stop Button Safety Relay
  • PLC Control Cabinet with Emergency Stop Button Safety Relay
  • PLC Control Cabinet with Emergency Stop Button Safety Relay
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
PASR-9000A
Condition
New
Customized
Non-Customized
Input Device
Emergency Stop Button/Safety Door
Supply Voltage
24V DC
Number of Channels
Dual Channel Input
Output Signal
Semiconductor Output
Reset Mode
Auto/Manual Reset
Contact Switching Capacity
5A
Transport Package
Box
Specification
ABSflame retardant
Trademark
PARAGON
Origin
China

Product Description

Product Description
PLC Control Cabinet with Emergency Stop Button Safety Relay
Detailed Photos
PLC Control Cabinet with Emergency Stop Button Safety RelayPLC Control Cabinet with Emergency Stop Button Safety Relay
Product Parameters
General
Number of channels Dual channel input
Switch capacity
Three normally open contacts AC15:5A/250VAC
DC13:6A/DC24V
Rated heating current Ith 5A
Insurance level 6A fast or 4A slow
Usage category AC-15,DC-13
Time
Dual channel input time Unlimited
Safe output time under rated voltage Manual start 35ms
Safe disconnection time under rated voltage 10ms
Contact material and structure AgSnO+0.2um Au, forced open contact
Contact resistance ≤100mΩ
Mechanical life 10 million times
Operation frequency 6 times/minute
Status display Three green LEDs
Start button monitoring Manual start/automatic start
Rated insulation voltage 300V (pollution level 2 according to IEC60947-5-1)
Rated impulse withstand voltage 2500V (Class 2 overvoltage according to IEC60947-5-1)
Applicable Emergency stop switch, safety door
Input data
Input channel Dual channel input
Input current ≤10mA
Wire resistance ≤15Ω
Output data
Output signal Semiconductor output
Output channel 3 normally open outputs (13-14,23-24,33-34)
One normally closed output (41-42)
Power supply
Supply voltage 24VDC
Voltage range 85%~110%
Module power consumption ≤3W(24VDC)
Overall dimension
Height 114.5mm
Width 99mm
Thickness 22.5mm
Housing
Material ABSflame retardant
Degree of protection IP20
Flammability rating UL94/V0
Colour Grey+Yellow
EMC data
Electrical fast transient/burst immunity Compliant with:IEC 61326-1;A-leve
Surge immunity Compliant with:IEC 61326-1;B-leve
Radiated,radio-frequency,electromagnetic field immunity Compliant with:IEC 61326-1;conform to basic requirements
Electrostatic discharge immunity Compliant with:IEC 61326-1;A-leve
Immunity to conducted disturbances, induced by radio-frequency fields Compliant with:IEC 61326-1;conform to basic requirements
Low frequency common mode conduction Compliant with:IEC 61326-1;conform to basic requirements
Compliant with standards BS EN 62061:2015,ISO 13849-1:2015,ISO 13849-2:2012, IEC EN 60204-1, ISO 13849-1
Safety Integrity Level (SIL) EN954-1, maximum safety control level 4
Performance level (PL) ISO 13849-1:2015,PLe
Operating conditions
Continuous operating temperature -20ºC~+60ºC
Storage temperature -40ºC~+85ºC
Relative humidity <90% RH (no condensate)
Environmental requirements There should be no strong vibrations, impacts, high currents, sparks or other electromagnetic induction effects in the surrounding environment. The air should not contain media that corrode chromium, nickel, and silver coatings, and should not contain flammable or explosive substances
Connection data
Conductor cross section solid range 0.5~2.5mm²
Conductor cross section AWG min. 12
Conductor cross section AWG max. 24
Stripping length 8mm
Screw thread M3
Connection method Screw connection
Tightening torque min. 0.5 Nm
Tightening torque max. 0.6 Nm
Installation
Installation method DIN35mm
Company Profile

 


PLC Control Cabinet with Emergency Stop Button Safety Relay
PLC Control Cabinet with Emergency Stop Button Safety Relay
PLC Control Cabinet with Emergency Stop Button Safety Relay
PLC Control Cabinet with Emergency Stop Button Safety Relay
PLC Control Cabinet with Emergency Stop Button Safety Relay
 
PLC Control Cabinet with Emergency Stop Button Safety Relay
PLC Control Cabinet with Emergency Stop Button Safety Relay
PLC Control Cabinet with Emergency Stop Button Safety RelayPLC Control Cabinet with Emergency Stop Button Safety Relay

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier