High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets

Product Details
Customization: Available
Task: Adjust
Structure: Combination
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
to see all verified strength labels (26)
  • High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
  • High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
  • High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
  • High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
  • High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
  • High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Overall dimension
  • Company Profile
Overview

Basic Info.

Model NO.
Drg-1500
Condition
New
Customized
Non-Customized
Number of Channels
1input/1output
Input Signal
Corresponding Thermocouple Measurement Range
Output Signal
4mA~20mA
Power Supply Mode
20~35V DC
Accuracy
0.2% F.S. (Typical Value: 0.05% F.S.)
Installation
35mm DIN Rail
Transport Package
Box
Specification
PC+ABSflame retardant
Trademark
PARAGON
Origin
China

Product Description

Product Description
High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
Detailed Photos
High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
Product Parameters
General
Number of channels 1input/1output
Output accuracy (20 ° C) 0.2% F.S. (typical value: 0.05% F.S.)
Temperature drift 0.01%F.S./ºC
Cold end compensation accuracy ±1ºC(0ºC~55ºC)
Response time 2ms to reach 90% of the final value
Insulation strength 1500VAC/min between intrinsically safe/non intrinsically safe terminals, 1000VAC/min between non intrinsically safe terminals
Insulation resistance Non intrinsic safety end - intrinsic safety end≥100MΩ, power supply - non intrinsic safety end≥100MΩ
Electromagnetic compatibility Compliant with IEC 61326-1(GB/T 18268),IEC 61326-3-1
EX marking [Ex ia Ga]IIC
Weight About 150g
Connected field equipment J,K,T,E,S,B,N,Rthermocouple
Applicable locations Zone 0, Zone 1, Zone 2, IIA, IIB, IIC hazardous areas
Input data
Input signal range Corresponding thermocouple measurement range
Input signal type Thermocouple millivolt signal (K, S, B, E, J, T, N, R, We5-26)
Output data
Output signal 4mA~20mA
Output load capacity 0~500Ω
Power supply
Supply voltage(Ue) 20~35V DC
Power protection Reverse protection of power supply
Power consumption 1W (24V power supply, 20mA output)
Power supply mode Independent power supply
Power connecting mode Terminal power supply;Base power supply
Overall dimension
Centralized power supply
Depth 120.8mm
Height 113mm
Width 13.3mm
Independent power supply
Depth 110mm
Height 108mm
Width 13.3mm
Housing
Material PC+ABSflame retardant
Degree of protection IP20
Flammability rating UL94/V0
Colour White+Grey
EMC data
Electrical fast transient/burst immunity Compliant with:IEC 61326-1;A-leve
Surge immunity Compliant with:IEC 61326-1;B-leve
Radiated,radio-frequency,electromagnetic field immunity Compliant with:IEC 61326-1;conform to basic requirements
Electrostatic discharge immunity Compliant with:IEC 61326-1;A-leve
Immunity to conducted disturbances, induced by radio-frequency fields Compliant with:IEC 61326-1;conform to basic requirements
Low frequency common mode conduction Compliant with:IEC 61326-1;conform to basic requirements
Operating conditions
Continuous operating temperature -20ºC~+60ºC
Storage temperature -40ºC~+80ºC
Relative humidity 35%~85%RH
Environmental requirements There should be no strong vibrations, impacts, high currents, sparks or other electromagnetic induction effects in the surrounding environment. The air should not contain media that corrode chromium, nickel, and silver coatings, and should not contain flammable or explosive substances
Connection data
Conductor cross section solid range 0.5~2.5mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M3
Stripping length 8mm
Connection method Screw connection
Tightening torque min. 0.5 Nm
Tightening torque max. 0.6 Nm
Installation
Installation method DIN35mm
Overall dimension
 1. Base centralized power supply typeHigh-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets2. Terminal powered type

High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets

Company Profile

 


High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
 
High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
High-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets
High-Performance Thermocouple Isolation Safety Barrier for PLC CabinetsHigh-Performance Thermocouple Isolation Safety Barrier for PLC Cabinets

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier