Cnex Isolator for Enhanced Current Source Detection in Cabinets

Product Details
Customization: Available
Task: Adjust
Structure: Combination
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
to see all verified strength labels (26)
  • Cnex Isolator for Enhanced Current Source Detection in Cabinets
  • Cnex Isolator for Enhanced Current Source Detection in Cabinets
  • Cnex Isolator for Enhanced Current Source Detection in Cabinets
  • Cnex Isolator for Enhanced Current Source Detection in Cabinets
  • Cnex Isolator for Enhanced Current Source Detection in Cabinets
  • Cnex Isolator for Enhanced Current Source Detection in Cabinets
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Overall dimension
  • Company Profile
Overview

Basic Info.

Model NO.
DRG-1100-ECC
Condition
New
Customized
Non-Customized
Number of Channels
1input/1output
Input Signal
4mA~20mA/1~5V
Output Signal
4mA~20mA/1~5V
Power Supply Mode
20~35V DC
Accuracy
0.2%Fs
Installation
35mm DIN Rail
Transport Package
Box
Specification
PC+ABSflame retardant
Trademark
PARAGON
Origin
China

Product Description

Product Description
Cnex Isolator for Enhanced Current Source Detection in Cabinets
Detailed Photos
Cnex Isolator for Enhanced Current Source Detection in Cabinets
Product Parameters
General
Number of channels 1input/1output
Output accuracy (20 ° C) 0.1% F.S. (typical value: 0.05% F.S.)
Temperature drift 0.005%F.S./ºC
Response time 2ms to reach 90% of the final value
Insulation strength 1500VAC/min between intrinsically safe/non intrinsically safe terminals, 1000VAC/min between non intrinsically safe terminals
Insulation resistance Non intrinsic safety end - intrinsic safety end≥100MΩ, power supply - non intrinsic safety end≥100MΩ
Electromagnetic compatibility Compliant with IEC 61326-1(GB/T 18268),IEC 61326-3-1
EX marking [Ex ia Ga]IC
Weight About 150g
Connected field equipment Two wire transmitter (HART); Three wire transmitter; Current source signal
Applicable locations Zone 0, Zone 1, Zone 2, IIA, IIB, IIC hazardous areas
Input data
Input signal 4mA~20mA/1~5V
Output data
Output signal 4mA~20mA/1~5V
Distribution output power supply When the output current is 20mA, the distribution voltage is greater than 16V
Power supply
Supply voltage(Ue) 20~35V DC
Power protection Reverse protection of power supply
Power consumption 1.5W (24V power supply, 20mA output)
Power supply mode Independent power supply
Power connecting mode Terminal power supply;Base power supply
Overall dimension
Centralized power supply
Depth 120.8mm
Height 113mm
Width 13.3mm
Independent power supply
Depth 110mm
Height 108mm
Width 13.3mm
Housing
Material PC+ABSflame retardant
Degree of protection IP20
Flammability rating UL94/V0
Colour White+Grey
EMC data
Electrical fast transient/burst immunity Compliant with:IEC 61326-1;A-leve
Surge immunity Compliant with:IEC 61326-1;B-leve
Radiated,radio-frequency,electromagnetic field immunity Compliant with:IEC 61326-1;conform to basic requirements
Electrostatic discharge immunity Compliant with:IEC 61326-1;A-leve
Immunity to conducted disturbances, induced by radio-frequency fields Compliant with:IEC 61326-1;conform to basic requirements
Low frequency common mode conduction Compliant with:IEC 61326-1;conform to basic requirements
Operating conditions
Continuous operating temperature -20ºC~+60ºC
Storage temperature -40ºC~+80ºC
Relative humidity 10%~90%
Environmental requirements There should be no strong vibrations, impacts, high currents, sparks or other electromagnetic induction effects in the surrounding environment. The air should not contain media that corrode chromium, nickel, and silver coatings, and should not contain flammable or explosive substances
Connection data
Conductor cross section solid range 0.5~2.5mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 8mm
Screw thread M3
Connection method Screw connection
Tightening torque min. 0.5 Nm
Tightening torque max. 0.6 Nm
Installation
Installation method DIN35mm
Attention
Usage restrictions 1. HHC (HART manual operator) cannot be used simultaneously in hazardous and safe areas 2. HHC (HART manual operator) used in hazardous areas must have explosion-proof certification
Overall dimension
 1. Base centralized power supply typeCnex Isolator for Enhanced Current Source Detection in Cabinets2. Terminal powered type

Cnex Isolator for Enhanced Current Source Detection in Cabinets

Company Profile

 


Cnex Isolator for Enhanced Current Source Detection in Cabinets
Cnex Isolator for Enhanced Current Source Detection in Cabinets
Cnex Isolator for Enhanced Current Source Detection in Cabinets
Cnex Isolator for Enhanced Current Source Detection in Cabinets
Cnex Isolator for Enhanced Current Source Detection in Cabinets
 
Cnex Isolator for Enhanced Current Source Detection in Cabinets
Cnex Isolator for Enhanced Current Source Detection in Cabinets
Cnex Isolator for Enhanced Current Source Detection in CabinetsCnex Isolator for Enhanced Current Source Detection in Cabinets

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier